Networking
Figure 4-5 shows the example network for commissioning the interconnection with the SIP
interface.
Figure 4-5 Example network for commissioning the interconnection with the SIP interface
UA5000
Router
SIP
P
V
M
D
A
3
2
0/11 0/12
A
3
2
NOTE
The UA5000 supports the independent upstream mode and the integrated upstream mode. The
commissioning task uses the independent upstream mode. If the integrated upstream mode is used, you
need to run the working mode command to set the working mode of the PVMD board to integrated
upstream mode.
Data Plan
In the commissioning task:
l Use the same IP address for the media stream and the signaling flow. Transmit the media
stream and the signaling flow upstream through the same Ethernet port.
l Use the default QoS policy for the upstream transmission of the media stream and the
signaling flow.
Table 4-5 shows the data plan for commissioning the interconnection with the MG interface
through SIP.
Table 4-5 Data plan for commissioning the interconnection with the MG interface through SIP
Type
Item Data
Parameters of
the media
stream and
Upstream interface of the media
stream and the signaling flow
0/4/0
UA5000 Universal Access Unit Product
Commissioning Guide-PVM CLI 4 Commissioning the Interconnection