Figure 4-2 Networking for the inband NMS
COM
ETH1
iManager U2000
UA5000
Router
ETH0
PVMB
NOTE
In the integrated upstream mode, the iManager U2000 connects to the internal network port of the PVMB/
PVMD control board through the IP network, and manages the device through the upstream network port
of the IPMB/IPMD control board.
Data Plan
Table 4-2 provides the data plan for configuring the inband NMS.
Table 4-2 Data plan for configuring the inband NMS
Device or Port
Item Data
NMS interface of the
UA5000
IP address 10.20.1.3/24
Default gateway 10.20.1.1/24
NMS name huawei
GET community name public
SET community name private
vlan_tag 1001
Trap destination host name public
Trap sending parameter list name public
Trap protocol version SNMP V2C
UA5000 Universal Access Unit Product
Commissioning Guide-PVM CLI 4 Commissioning the Interconnection
Issue 04 (2012-06-25) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.