EasyManua.ls Logo

Husmann SPB - Machine-Specific Safety Regulations

Default Icon
113 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
4.2.2
Machine-specific safety regulations
The following safety instructions must be observed and used in addition to the instruc-
tions contained in these operating instructions.
Pay attention to the operating instructions in detail.
Make sure that there is no person in the compaction chamber.
The machine may only be operated by one person at a time.
Climbing onto the machine is prohibited!
It is prohibited to enter the compactor or the compaction chamber!
At an inclination of > 5 °, the compactor may only be operated with brake shoes (if the
compactor is equipped with four rollers)!
Do not compact material that could lead to dangerous situations or damage to the machine
(e.g. objects that could be thrown out of the compactor, explosive substances, metals, de-
molition waste, ashes)!
Depending on the customer's order and the machine design, the compactor is only ap-
proved for the compaction of household waste, industrial waste, fruit crates, cardboard
boxes, bulky waste or wet waste.
The vertical distance between the standing level and the filling edge must not be less than
1100 mm.
When working on ramps or when using podiums, these must be fitted with a railing ac-
cording to the current regulations!
Unattended operation in public places is not permitted.
The manipulation or removal of safety devices, safety covers or control devices is not per-
mitted!
Maintenance or repair work may only be carried out by staff specially trained for this task!
Prior to cleaning and maintenance work, the system must be disconnected from the main
power supply and secured against being switched on again by closing the main switch with
a personal padlock!
After maintenance and repair work, disassembled covers must be properly fastened and
missing screws replaced.
Only use suitable and tested connecting cables (H07 RN-F according to VDE 0100) for the
intended use!
Operation without a three-pole circuit breaker is not permitted!
The electrical machine can only be operated outdoors with an FI fuse with a maximum
residual current of 30mA.
Under no circumstances should the setting of the pressure switches be changed. In case of
replacement, only use original spare parts with an operating pressure of min. 200 bar.
If the material to be compacted is jamming or bridging, do not poke with an object.