146
9.5 Detail Connection Diagram
(Note) The user must provide the two-paired shielded cable.
If cables other than the recommended brands are connected to [A] and [B], use those with a
cable-sheath outer diameter of 1.35 to 1.60 mm.
Accessories (Optional):
[1] Controller link cable CB-RCB-CTL002 (connector on both ends), length 200 mm
[2] Four-way junction, made by AMP: 5-1473574-4
[3] E-Con connector, made by AMP: 4-1473562-4 (green)
[4] Terminal resistor 220 (with E-Con connector)
Of the above, [2], [3] and [4] are provided for the same number as the controller link cables. Therefore, not
all units are needed when multiple axes are used.
1
2
SIO converter
Two-paired shielded cable
Recommended brand:
Taiyo Electric Wire & Cable
HK-SB/20276XL
2PX22AWG
Four-way junction (AMP: 5-1473574-4)
A
B
EMG2
EMG1
24V
0V
FG
1
2
3
4
1
2
7
1
2
7
SGA
SGB
GND
Yellow
Orange
Blue
Yellow
Orange
Blue
Housing color: Green
Controller link cable
CB-RCB-CTL002
E-Con connector (AMP: 4-1473562-4)
Controller 1
E-Con connector (AMP: 3-1473562-4)
Housing color: Orange
TB1
TB2
Controller 2
[B]
1
2
3
4
1
2
3
4
1
2
3
4
SGA
SGB
GND
[A]