Quick Start Guide ~ RCON PROFINET IO Specification ~
p46
©2023 / IAI Corporation
STEP
3
STEP
1
STEP
2
Initial Setting
Table
of
Contents
Complement
Initial Connection between RCON Gateway Unit and IA-OS /
Axis Quantity Setting
The “IA-OS Main Window” opens.
(8)
When there is no IA-OS main window status shown, it means the
communication is not established.
In case the communication is not established, check the condition of insertion
and breakage of the communication cable connected to the controller.
“IA-OS Main Window”
Status of connected
controller or driver should
be displayed.
”Confirmation at Initial Connection” window
Make sure to establish the following setting at the initial connection.
Without setting the number of axes of the driver to the gateway unit,
communication with the driver unit or ELECYLINDER cannot be established.
Once “Confirmation at Initial Connection” window is open, click [Yes] .
(1)
The “Confirmation for Initial Connection” window should appear at the initial
connection between the gateway unit and IA-OS.
By establishing the setting as it shows below, the number of axes of driver to be
connected to the gateway unit and the number of option units to be connected
can be set up.
(1)
Click