Chapter 5 Customer Engineer (CE) Tests
Top Exit Tear Distance:
This parameter allows adjustment in 0.01 inch increments of the final location
of page perforations when top paper exit is used.
Shuttle Speed:
Sets shuttle speed in 6400-004, -04P, -005, and -05P printers. See page 182.
Set Coil Temperature:
An automatic sequence in printer software that recalibrates hammer coil
temperature. This procedure applies only to 6400-014 and 6400-15 printers.
See page 181.
Selecting And Running CE Tests
To run CE Tests you use the printer configuration menus, as shown below:
Step Press Displayed Result Notes
1. Install the ribbon, load paper, and power on the printer.
2.
NOT READY
Printer must be in NOT
READY mode to access
the tests.
3.
SERVICE
PRINTER MECHANISM TESTS
Press all four keys at the
same time.
4.
PRINTER MECHANISM TESTS
Burn In Test
Press Enter to view the
different mechanism
tests.
5.
PRINTER MECHANISM TESTS
Plot Test
Cycles through list of
tests. Stop when your test
displays.
6.
OPERATOR MENU
UNLOCKED
Unlocking ENTER key
allows you to test the
printer.
7.
Plot Test
Running
The test you selected
starts printing. See
Chapter 6 for instructions
in the use of the Hammer
Phasing and End of
Forms Adjust tests.
Stop
+
Scroll↑ Scroll↓
+
Return Enter
Enter
UNTIL
Scroll↑
+
Scroll↑ Scroll↓
Enter

Table of Contents

Other manuals for IBM 6400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 6400 and is the answer not in the manual?

IBM 6400 Specifications

General IconGeneral
BrandIBM
Model6400
CategoryPrinter
LanguageEnglish

Related product manuals