EasyManua.ls Logo

IBM 6400 - Appendix D: Installing the MPI on the Printer

IBM 6400
422 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Message List
93
110 STACK
OVERFLOW
SEE USER’S GUIDE
System stack has run
out of room and
overflowed into other
memory.
1. Cycle power. Run the print job again. If
the message appears, download the
emulation software again.
2. Cycle power. Run the print job again. If
the message appears, replace the CMX
controller board. Record the message
and return it with defective CMX board.
111 STACK
UNDERFLOW
SEE USER’S GUIDE
Firmware error on the
CMX controller board.
1. Cycle power. Run the print job again. If
the message appears, download the
emulation software again.
2. Cycle power. Run the print job again. If
the message appears, replace the CMX
controller board. Record the message
and return it with defective CMX board.
112 UNDEFINED
OPCODE
SEE USER’S GUIDE
Firmware error on the
CMX controller board.
1. Cycle power. Run the print job again. If
the message appears, download the
emulation software again.
2. Cycle power. Run the print job again. If
the message appears, replace the CMX
controller board. Record the message
and return it with defective CMX board.
113 PROTECTED
INSTRUCTION
SEE USER’S GUIDE
Protected Instruction.
Firmware error on the
CMX controller board.
1. Cycle power. Run the print job again. If
the message appears, download the
emulation software again.
2. Cycle power. Run the print job again. If
the message appears, replace the CMX
controller board. Record the message
and return it with defective CMX board.
114 ILLEGAL
OPERAND ACCESS
SEE USER’S GUIDE
Illegal Operand
Accessed. Firmware
error on the CMX
controller board.
1. Cycle power. Run the print job again. If
the message appears, download the
emulation software again.
2. Cycle power. Run the print job again. If
the message appears, replace the CMX
controller board. Record the message
and return it with defective CMX board.
115 ILLEGAL
INSTRUCTION
ACCESS
SEE USER’S GUIDE
Illegal Instruction
Accessed. Firmware
error on the CMX
controller board.
1. Cycle power. Run the print job again. If
the message appears, download the
emulation software again.
2. Cycle power. Run the print job again. If
the message appears, replace the CMX
controller board. Record the message
and return it with defective CMX board.
Table 4. Message List
Operator Panel
Message
Explanation Corrective Action

Table of Contents