Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
20E00017 Cold boot needed for password entry. Turn off, turn on system unit.
20EE0003 IP parameter requires 3 dots . Enter valid IP parameter.
Example: 000.000.000.000
20EE0004 Invalid IP parameter. Enter valid (numeric) IP parameter.
Example: 000.000.000.000
20EE0005 Invalid IP parameter (>255) Enter valid (numeric) IP parameter in
the range of 0 to 255.
Example: 255.192.002.000
20EE0006 No SCSI controllers present The system board should always have
at least 2 integrated PCI SCSI
controllers; one internal and one
external. Replace the system board.
Location: P1
(See notes on page 115.)
20EE0007 Keyboard not found 1. Plug in keyboard.
2. Replace the system board.
Location: P1
(See notes on page 115.)
20EE0008 No configurable adapters found in the
system by the remote IPL menu in the
SMS utilities.
This warning occurs when the remote
IPL menu in the SMS utilities cannot
locate any LAN adapters that are
supported by the remote IPL function.
If a supported device is installed:
1. Replace the adapter.
2. Replace the system board.
Location: P1
(See notes on page 115.)
20EE0009 Unable to communicate with service
processor
Replace the system board.
Location: P1
(See notes on page 115.)
118 Service Guide