EasyManua.ls Logo

IBM 6C1 - Operator Panel; Removal; Replacement

IBM 6C1
377 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operator Panel
The following procedures cover removal and replacement of the operator panel.
Removal
1. If you have not already done so, shut down the system as described in “Stopping
the System” on page 254.
2. If you have not already done so, unplug the system power cables from the electrical
outlets.
3. If your system is a Model 6C1 (rack mount), place the system in the service position
as described in “Placing the Model 6C1 in the Service Position” on page 255.
4. Remove the service access cover. See “Covers” on page 258.
5. Remove the bezel as described in “Bezels” on page 262.
6. Remove the operator panel by grasping the release levers and pulling the operator
panel tray from the system.
7. If installed, remove the cables from the disk drive.
8. Disconnect the cables from the operator panel and remove the operator panel.
Replacement
1. To replace, perform removal steps in reverse order.
2. Complete the VPD update procedure as described in “System Vital Product Data
(VPD) Update Procedure” on page 288.
Chapter 9. Removal and Replacement Procedures 287

Table of Contents