Specifications
Dimensions Rack (Model 6C1) Tower (Model 6E1)
Height 215 mm 8.5 in. 426 mm (16.8 in.)
5 EIA Units
Width 426 mm 16.8 in. 215 mm (8.5 in.)
Depth 617 mm 24 in. 617 mm (24 in.)
Weight
Minimum configuration 35.5 kg 78 lbs.
Maximum configuration 43.1 kg 94.8 lbs.
Electrical
Power source loading
(maximum in kVA)
0.46
Power source loading (typical
in kVA)
0.31
Voltage range (V ac) 100 to 127 or 200 to 240 (autoranging)
Frequency (hertz) 50 / 60
Voltage range (V dc) Not supported
Thermal output (maximum) 1536 Btu/hr
Thermal output (typical) 1024 Btu/hr
Power requirements
(maximum)
450 watts
Power requirements (typical) 300 watts
Power factor - US, World
Trade, Japan
0.98
Inrush current² 70 amps
Maximum altitude³, 2135 m (7000 ft.)
Temperature Requirements³ Operating
10 to 40°C
(50 to 104°F)
Non-Operating
10 to 52°C
(50 to 126°F)
Humidity Requirements Operating Non-Operating
(Noncondensing) 8 to 80% 8 to 80%
Wet Bulb 27°C (80°F) 27°C (80°F)
Model 6E1 Noise
Emissions¹,
Operating Idle
L
WAd
6.1 bels 6.1 bels
<L
pA
>
m
42 dBA 41 dBA
Model 6C1 Noise
Emissions¹,
Operating Idle
L
WAd
6.4 bels 6.1 bels
<L
pA
>
m
44 dBA 41 dBA
Install/Air Flow Maintenance of proper service clearance should allow proper
air flow.
Chapter 1. Reference Information