Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
25A80012 Data corruption detected, some data
partitions may have been preserved.
Refer to NVRAM error notes on page
123.
25A80100 NVRAM data validation check failed. Turn off, turn on system unit and retry
the operation before replacing any
system component. Refer to NVRAM
error notes on page 123.
25A80201 Unable to expand target partition while
saving configuration variable.
Refer to NVRAM error notes on page
123.
25A80202 Unable to expand target partition while
writing error log entry.
Refer to NVRAM error notes on page
123.
25A80203 Unable to expand target partition while
writing VPD data.
Refer to NVRAM error notes on page
123.
25A80210 Setenv/$Setenv parameter error - name
contains a null character.
Refer to NVRAM error notes on page
123.
25A80211 Setenv/$Setenv parameter error - value
contains a null character.
Refer to NVRAM error notes on page
123.
124 Service Guide