Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
25Cyy006 Memory DIMM failed inter-extent test. 1. Replace the memory card.
Location: P1-M1
2. Replace the processor card.
Location: P1-C1
Location: P1-C2
See Memory Error Notes on page 126
for more information.
25Cyy007 Memory DIMM failed extent access test.
1. Replace the memory card.
Location: P1-M1
2. Replace the processor card.
Location: P1-C1
Location: P1-C2
See Memory Error Notes on page 126
for more information.
25Cyy008 Memory DIMM has been deconfigured.
1. Use the memory config/deconfig
menu in the Service Processor
System Information Menu to check
the status of the memory DIMMs.
2. Go to “MAP 1240: Memory
Problem Resolution” on page 49.
26020001 Invalid PCI adapter vendor ID.
1. Move adapter to another slot
(behind another PCI bridge).
2. Check for available firmware
updates for adapter. Apply update
if available.
3. Run AIX diagnostics on adapter.
Replace if indicated.
4. Replace adapter.
5. Check for system firmware
updates. Apply if update available.
6. Replace system board.
Location: P1
(See note 3 on page 115.)
Chapter 5. Error Code to FRU Index