Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
40110010 Current sharing fault detected in power
supply main enclosure
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Reseat the power supplies
3. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
40110011 DC_GOOD fault detected in main power
supply enclosure
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Reseat the power supplies
3. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
40110013 Only one power supply is present; two
are required
Install an additional power supply. Two
power supplies are required.
40110014 Overcurrent detected on 5 volt line in
power supply main enclosure
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Look at the service processor error
log for more error information.
3. Reseat the power supplies
4. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
40111002 Unknown power problem detected.
1.
If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3