Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
40111062 Overvoltage detected on the -12 volt line
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
40111072 A high +5 V standby voltage reading
detected.
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
40111082 A low 5.0 V reading detected.
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
148 Service Guide