Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
401110C2 A low -12 V reading detected.
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
401110D2 A low +5 standby V reading detected.
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
40111101 Power good signal low on either
processor card 1 or processor card 2.
If AIX is running, check the AIX error
log to find out which processor card is
failing. If AIX in not available, check
the service processor error log.
Replace the failing processor.
Location: P1-C1 or P1-C2.
40111102 Wrong processor card plugged into the
system.
1. Remove processor cards.
2. Verify FRU number of new
processor card is correct before
installation.
40111122 High PCI +5.0 voltage reading detected
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
150 Service Guide