Step 1540-8
One of the FRUs remaining in the system unit is defective.
1. Turn off the power and remove the power cords.
2. Exchange the following FRUs in the order listed.
a. Memory card
b. System board (see notes on page 35)
c. Power supply
3. Plug in the power cords and wait for the OK on the operator panel display.
4. Turn on the power.
Does the system stop with code E1F2, E1F3, STBY or 4BA00830 displayed on the
operator panel?
NO Reinstall the original FRU.
Repeat this step until the defective FRU is identified or all of the FRUs have
been exchanged.
If the symptom did not change and all the FRUs have been exchanged, call
service support for assistance.
If the symptom has changed, check for loose cards, cables, and obvious
problems, return to “Step 1540-1” on page 64 in this MAP, and follow the
instructions for the new symptom.
YES Go to MAP 0410: Repair Checkout in the
RS/6000
Eserver
pSeries
Diagnostic Information for Multiple Bus Systems
.
Chapter 3. Maintenance Analysis Procedures (MAPs) 69