Rev AA Default Options Configuration 3-30
Devices,
Phds,1
Print
Information
Unprinted Pack
Behavior
None None No Fault There are 3 options.
1)
No fault. The coder carries on wit
hout error if
th
ere are uncoded or under speed packs
2) Fault
on all undersized packs. Stop with
fault
whenever the film
speed drops below 40mm/s AND
a second print signal is received before the first
print completes.
3) Fault on unprinted packs. Stop with a fault when
a second print signal is received before the first
print is completed, regardless of film speed.
Vertical
Registration
Vertical
Registration
mm 0 Moves the image across the width of the printhead
Profiler Capture
Encoder Profile
Capture
Encoder
Profile
None None Triggers the capturing of an encoder profile
Imaging
Printhead
Mapping
None None Printhead 1 Required parameter -do not adjust
Printer Codes
Factory ID None None 1 Allows the setting of a unique special code for the
Factory ID. It is a global setting for the printer and
all layouts that reference a factory ID code print this
value
Line ID None None 1 Allows the setting of a unique special code for the
production Line ID. It is a global setting for the
printer and all layouts that reference a Line ID code
print this value
Section Sub-Section Parameter
Name
CLARiTY
Name
Units Default Functionality
Table 3-1: Videojet 6210 Printer Configuration Manager (Continued)