69
8
GPS/GPS-A OPERATION (Optional UT-121 is required for IC-92A)
New2001
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
D-Alarm area 1
Sets GPS alarm active range within 00c05s to 59c59s in
1 sec.
(00c01s) steps. (default: 00c15s)
q Enter “GPS MEMORY” in message/position set mode.
w The alarm area 1 function is available when “GPS
ALARM” function of ALL or BANK A–Z turns ON.
D-Alarm area 2
Selects GPS alarm active range from “LIMITED, “EX-
TENDED” and “BOTH.
•-LIMITED : GPS alarm will be sound when a
target position is coming into 500 m*
(547 Y)* range.
•-EXTENDED : GPS alarm will be sound when a
target position is coming into 1 km*
(1094 Y)* range.
• BOTH : GPS alarm will be sound when a
target position is coming into both
500 m*
(547 Y)* and 1 km* (1094 Y)*
range.
(default)
*Approximate
00
15
00
15
00
15
00
15
Your position
Point A
Point C
Point B
Point D
N
• Example:
Your position : 35˚N/135˚E
ALM AREA1 setting : 0015
(default)
• Position of point A : 35˚0015N/134˚5945E
• Position of point B : 35˚0015N/135˚0015E
• Position of point C : 34˚5945N/134˚5945E
• Position of point D : 34˚5945N/135˚0015E
When the target position is coming into the area as above, the
GPS alarm will be sound.
Extended range
(approx. 1 km; 1094 Y)
Limited range
(approx. 500 m; 547 Y)
Your position
• Example:
When the target position is coming into either/each area as
above, the GPS alarm will be sound.
MENU screen
MESSAGE/POSITION
GPS SET MODE
(Push [MENU/ ]) (Rotate [DIAL]
, then push [ ](5)
.)

Table of Contents