User Manual uEye Cameras V3.32
Internal supply voltage by sensor type
3.0 V
3.3 V
164xLE
155xLE
148xLE
122xLE
154xLE
146xLE
If the 3V3 and the 5V power supplies are used simultaneously, please observe that the
maximum power available from the USB bus is 2.5 W.
I2C operation
Multi master mode is not allowed on the I2C bus while the USB uEye LE camera is used.
From driver version 3.20, the I2C bus is operated with an effective clock frequency of
approx. 250 kHz. For earlier versions, the clock frequency is 100 kHz.
Digital Input Wiring (Trigger)
Digital input specifications
Min.
Max.
Level low
0
0.8
V
Level high
2.0
5.25
V
The digital input of the USB uEye LE is not potential-free and has no protective circuits.
Due to hardware limitations, the USB uEye LE can only be triggered on the falling edge.
Digital input wiring
Figure 183: Wiring of the trigger connector

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDS uEye series and is the answer not in the manual?

IDS uEye series Specifications

General IconGeneral
SensorCMOS
InterfaceUSB 2.0, USB 3.0, GigE
ShutterGlobal or Rolling Shutter
Power SupplyVia USB or external power (depending on model)
Operating SystemWindows, Linux
MountC-mount or CS-mount
Dimensions29 x 29 x 29 mm