The priority of a recorder output that is in conflict is:
a. Aggregate Rate/Thickness on the Primary Layer (the first of two
co-deposited layers).
b. Aggregate Rate/Thickness on the Secondary Layer (the second of two
co-deposited layers).
c. Sensor Rate/Thickness on the Primary Layer (from sensors 1 to 8).
d. Sensor Rate/Thickness on the Secondary Layer (from sensors 1 to 8).
For a Sensor’s Recorder Output to be active it must be associated with an