EasyManua.ls Logo

INIM Electronics Prime - Appendix F Event type; Event type

INIM Electronics Prime
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
100 Event type
Centrali anti-intrusione
Appendix
F
Event type
Name Occurs when... Restores when ... Number of events
Pulse
events
Zone alarm
Zone alarm
A zone generates an alarm A zone restores
One event for each
zone
no
Terminal tamper
Terminal tamper
A terminal detects tamper (short-circuit
or wire cutting)
A terminal restores
One event for each
terminal
no
Partition alarm
Partition alarm
A 24h zone which belongs to the partition
generates an alarm, or a zone which
belongs to the partition generates an
alarm during Away mode.
All the zones belonging to the
partition restore (reset).
One event for each
partition
no
Alarm partition armed
in Stay mode
StayPartit.alarm
A zone which belongs to a partition armed
in Stay or Instant mode, generates an
alarm.
All the zones belonging to the
partition restore (reset).
One event for each
partition
no
Partition tamper
Partition tamper
A zone which belongs to the partition
detects tamper (short-circuit or wire cut-
ting).
All the zones belonging to the
partition restore (reset).
One event for each
partition
no
Zone bypass
Zone bypass
A zone is inhibited A zone is enabled (switched On)
One event for each
zone
no
Real time zone
Real-time zone
The electrical status of a zone switches
from stand-by to alarm
The electrical status of a zone
switches from alarm to stand-by
One event for each
zone
no
The event is independent of the zone type and the armed/disarmed status
of the partitions.
Partition not-ready-to-
arm
Partit.not ready
A zone which belongs to the partition is
not in stand-by status.
All the zones belonging to the
partition are in standby status.
One event for each
partition
no
Away arming request
on partition
Away arm request
A request is made to arm the interior and
perimeter zones of the partition
A request is made to disarm the
partition
One event for each
partition
Yes
Stay arming request
on partition
Overtime request
A request is made to arm the partition in
Stay mode (perimeter zones only) or in
Instant mode
A request is made to disarm the
partition
One event for each
partition
Yes
Effective arming mode
on partition
Partit.AwayArmed
The partition interior and perimeter zones
have been armed effectively
The partition will be disarmed
One event for each
partition
no
Partition armed in
Away mode
Partit.StayArmed
armed
The partition has been armed effectively
in Stay or Instant mode
The partition will be disarmed
One event for each
partition
no
Disarm partition
Disarm partition
The partition will be disarmed The partition will be armed
One event for each
partition
no
Reset partition memo-
ries
Partition reset
A request is made to reset the partition
One event for each
partition
Yes
Partition exit time
Exit time
The partition exit time starts running The partition exit time expires
One event for each
partition
no
Partition entry time
Entry time
The partition entry time is running The partition entry time expires
One event for each
partition
no
Partition pre-arm time
Pre-arm time
The partition Pre-arm time is running
The partition Pre-arm time
expires
One event for each
partition
no
Overtime request on
partition
Overtime request
A request for overtime relating to the par-
tition is made
One event for each
partition
Yes
Partition bell
Chime
A chime zone belonging to the partition is
violated
One event for each
partition
Yes
Forced arming on par-
tition
Forced arming
At the time of an arming command, relat-
ing to one or more partitions, there are
open zones on the partition/partitions
involved, or there are other conditions
present which lower system security,
nonetheless, the user arms the system.
One event for each
partition
Yes
Partition failed to arm
Failed to arm
If partition arming is requested whilst:
there is at least one open/violated zone
and the option “NoArm.ZonesOpen” is
enabled
or
when one or more of the events
described in “LossTamp.ongoing” is pres-
ent (refer to “FaultForNotReady”, para-
graph 4-5 Compliance 50131 grade 3).
One event for each
partition
Yes
Recognized valid user
code
Valid code
A user-code PIN entered at a keypad is
recognized as valid
One event for each
code
Yes
Valid key
Valid key
A key used at a reader is recognized as
valid on the reader
One event for each
key
Yes

Table of Contents