68 Programming the PrimeLAN board
Centrali anti-intrusione
The activation of an action in the Prime control panel triggered by a signal from a KNX system
depends on the value of the bit that accompanies each telegram and on the selection of one of
the “execute” parameters indicated above. Following is an explanatory table:
13-5
Updating the PrimeLAN
firmware
Through a direct connection between the Prime/STUDIO software and the Prime control panel,
it is possible to update the control panel firmware to the latest revision available at moment of
the software release.
Via software
Click-on the
Firmware upgrade
button on the menu on the left, the “Programming” section
will show the buttons for the updating procedure.
Click-on the
PrimeLAN board
button. A section will open with the available updates and the
Start procedure button.
ATTENTION!
In order to avoid invalidating the procedure, do not switch off or disconnect the PC or Prime
control panel during the updating process.
Table 13-6: Signals from KNX system to Prime control panel
Parameter Software section
KNX Event
Field for the insertion KNX telegram, signal from the KNX system corresponding
to an event.
Programming
KNX, From KNX to
control panel
...
Button to open the "Add KNX telegram" window.
Actions on control
panel
Check box to indicate the action to be activated on the Prime control panel.
Element /Mode
Action parameter.
Execute if bit=0
Options that activate the action on the control panel depending on the bit
associated with the signal from the KNX.
Execute if bit=1
Execute anyway
Execute as a bit
Delete
Button to delete the corresponding event from the list
Table 13-7: Actions on control panel from KNX system
Action Execute if bit=0 Execute if bit=1 Execute anyway Execute as a bit
on control
panel
Mode bit=0 bit=1 bit=0 bit=1 bit=0 bit=1 bit=0 bit=1
Arm in Stay
mode
Away mode
Activation
action
No action No action
Activation
action
Activation
action
Activation
action
Activation
“Disarm”
Activation
action
Stay Arm
Activation
action
No action No action
Activation
action
Activation
action
Activation
action
Activation
“Disarm”
Activation
action
Instant mode
Activation
action
No action No action
Activation
action
Activation
action
Activation
action
Activation
“Disarm”
Activation
action
Disarm
Activation
action
No action No action
Activation
action
Activation
action
Activation
action
No action
Activation
action
Reset
Activation
action
No action No action
Activation
action
Activation
action
Activation
action
No action
Activation
action
Zone bypass
Bypass
Activation
action
No action No action
Activation
action
Activation
action
Activation
action
Activation
“Unbypass”
Activation
action
Unbypass
Activation
action
No action No action
Activation
action
Activation
action
Activation
action
Activation
“Bypass”
Activation
action
Activate exit
Activation
Activation
action
No action No action
Activation
action
Activation
action
Activation
action
Activation
“Deactiva-
tion”
Activation
action
Deactivation
Activation
action
No action No action
Activation
action
Activation
action
Activation
action
Activation
Activation”
Activation
action
Activation
scenario
Activation
Activation
action
No action No action
Activation
action
Activation
action
Activation
action
No action
Activation
action

Table of Contents

Related product manuals