Programming partitions
The programming of the partitions of the Prime system can be performed either via software
or from a keypad.
Via software
Click-on the
Partitions
button on the menu on the left, the “Programming” section will show
a list of all the available partitions and their parameters. By selecting one of these items it is
possible to set the parameters of the single partition by clicking on the button.
Via keypad
Type-in Code
(Installer PIN)
, PROGRAMMING Partitions
This section allows you to program the various options of the selected partition.
5-1
Partition parameters
AUTOMATIC ARM/
DISARMING
The association of a timer to a partition will allow it to arm or disarm automatically at the ON/
OFF times set on the timer.
This function must be enabled or disabled for each individual partition.
Type-in Code
(User)
, Activations, Auto-arm
This section lists the partitions on which to activate or not automatic arm/disarm operations
by means of the and buttons.
Forced auto-arm operations may occur, generated by events active at the time of the auto-
arm operation.
Table 5-1: Parameters for single partitions
Parameter Software section Installer menu section
Description
This is the editable partition label (description).
Partitions,
selected
partition
Partitions, "parti-
tion"
Exit time
This is the Exit time window (programmable in seconds or
minutes).
If you set “0” in this field, there will be no Exit time.
Therefore, any delayed zones belonging to the partition will
generate alarms instantly if they are not in stand-by status
when the partition is armed.
Entry Time
This is the Entry time window (programmable in seconds or
minutes).
If you set “0” in this field, there will be no Entry time.
Therefore, any delayed zones belonging to the partition will
generate alarms instantly if violated when the partition is
armed.
Entry Time 2
This is the window for the second Entry time.
Pre-arm time
This setting is the delay, expressed in minutes, which
precedes automatic-arming on a partition.
Patrol time
This is the time window for patrol operations
(programmable in minutes).
Timers
Select the timer you want to associate with the automatic-
arming operations.
Autoreset memory
on arming
If enabled, the partition alarm and tamper memory will
reset automatically when the partition arms.
Partitions, "parti-
tion", Options,
AutoresetMemories
Auto-arm in stay
mode
If enabled, the partition will arm in “Stay” mode at the
programmed time.
If disabled, the partition will arm in “Away” mode at the
programmed time.
Autoarm.STAYmode
Clear call queue on
disarm
If enabled, the call queue will clear when the partition
disarms.
StopTelOn Disarm
Events button
At the bottom of the section are the buttons that directly
access the programming section of the events associated
with the selected partition.
Events