92 Default programming
Centrali anti-intrusione
Appendix
A
Default programming
Keypads
keypad “1” enabled
all keypads belong to partition 1
12 programmed shortcuts: Execute Arming Scenario 1 - Execute Arming Scenario 2 -
Delete telephone calls - Delete memory - Zone activation menu (bypasses) - View alarm
log - View faults - Time/date setting - Voice function menu - Intercom call - Thermostat
menu - Keypad settings menu
nBy Readers
belong to partition 1
shortcut programmed on the red LED: Execute Arming Scenario 1
Partitions
entry time and exit time 30 seconds
Autoreset memories on arming
clear call queue on disarming
Terminals
terminals on control panel: inputs
terminals on expansion boards: inputs
terminals on keypads: unused
Zones
belong to partition 1
have N.C. balancing (normally closed)
zones T1 and T2 on the control panel are delayed; all other zones are instant
unlimited alarm cycles (repetitive)
Outputs
the output relay is monostable, normally closes, monostable time at 3 minutes
Scenarios
scenario 1: Away arm partition 1
scenario 2: Disarm partition 1
Codes
user code 1 belongs to all partitions
all other codes do not belong to any partition
only Code 1 is “Master” user
enabled on all sections of the user menu
8 programmed shortcuts (keys F1-F4): Clear call queue - Activation Output 2 -
Deactivation Output 2 - View zone status - View system status - Enable answerphone -
Enable Teleservice - Teleservice request
6 programmed shortcuts (keys 1 to 6): Listen-in - Execute Scenario 1 - Execute Scenario 2
- Stop alarms - Activate Output 2 - Deactivate Output 2
voice guide enabled
Keys
belong to partition 1
Maintenance option enabled
Telephone
contact numbers 1 to 6 in the phone book have the voice attribute (user)
contact numbers 7 and 8 in the phone book are for alarm receiving centres CONTACT-ID
contact number 9 in the phone book has the voice attribute (for the installer)
contact number 15 is for teleservice