28 Programming from the Control panel
Centrali anti-intrusione
4-4
“Cloud mode” preset
In order to make it easier for the installer to program a Prime panel registered with the Inim
Cloud service, the software has an option that, if enabled, provides a preset of some of the
control panel parameters that would otherwise have to be programmed individually.
If activated, the software will perform the following default programming: A preset of events
of various types will be applied and must be communicated to the Cloud when they occur.
Domain
User name
Password
If you have a dynamic public IP address, you may find it
useful to use a domain name which will allow you to
trace the LAN board at all times.
Prime supports the service offered by:
•dyndns.org
• freedns.afraid.org
• no-ip.com
• camsec.net
• inimdns.biz
By registering at one of these addresses, you will obtain
the access data required in this programming section:
IP Connection
parameters, DNS
dynamic
Not available
Update every
This interval (expressed in seconds) will be applied by
the LAN when updating the association of the selected
domain with the public IP address.
Not available
Check DDNS
account
This button start the DDNS account verification (for
"inimdns.biz" service only).
Not available
Enable NTP syn-
chronization
If enabled, the Prime control panel clock will be
synchronized with NTP protocol, therefore, it will be
necessary to indicate:
• Server
• Update every - this is the time, expressed in
seconds, that elapses between successive time
updates.
IP connection
parameters,
Configure NTP
client
Not available
Enable Modbus
If enabled, the Modbus/IP service on the LAN board will
be activated; in this case it is necessary to indicate:
• Port
• Access Codes
Connection
parameters,
Modbus
Not available
This section allows you to program the parameters of the IP connection
test.
IP connection
parameters, IP
connection test
parameters
Not available
IP address
Port
Pv4 Address and port connection attempts are directed
to.
Not available
Interval
Time, expressed in seconds, between connection tests. If
“0” is set, the connection test will be disabled.
Not available
Number of
attempts
Number of connection attempts for each test. Not available
Table 4-4: IP connection
Table 4-5: Preset events for the Cloud
Event
Communication to Cloud in case of
Event
Communication to Cloud in case of
Activation Restoral Activation Restoral
Zone alarm Yes Yes Reader Tamper Yes Yes
Terminal tamper Yes Yes Sounder flasher tamper Yes Yes
Zone bypass Yes Yes Nexus tamper Yes Yes
Effective arming mode on parti-
tion
Yes No Video detector tamper Yes Yes
Partition armed in Away mode Yes No Expansion Loss Yes Yes
Partition disarmed Yes No Keypad Loss Yes Yes
Overtime request Yes No Reader Loss Yes Yes
Partition failed to arm Yes No Sounder/flasher loss Yes Yes
Thermostat on keypad Yes Yes Nexus loss Yes Yes
Activate scenario Yes No Video detector loss Yes Yes
Emergency button Yes No Jamming Yes Yes
Panic Yes No Low battery wireless zone Yes Yes
Open-panel tamper Yes Yes Wireless zone loss Yes Yes
Dislodged-panel tamper Yes Yes Valid Installer code Yes No
Zone fuse fault Yes Yes Invalid code Yes No