50 Programming keys
Centrali anti-intrusione
10-2
Key parameters
Via software
Click-on the
Keys
button on the menu on the left, the "Programming" section will show a list
of all the available keys and their parameters. By selecting one of these items it is possible to
set the parameters of the single key by clicking on the button.
Via keypad
Type-in Code
(Installer)
, PROGRAMMING Keys, "key", Key parameters
This section allows you to program the various options of the selected key.
The shortcut associated with the key can be one of the following types:
-None
-Arm/Disarm
-Stop alarms
-Clear call queue
- Delete memory
- Activate output
- Deactivate output
-Overtime
- Teleservice request
-Voice guide
-Panic
If a digital key is held in the vicinity of a reader, the LEDs will run through a series of visual
signals with the following meanings:
Table 10-1: Parameters for single key
Parameter Software section Installer menu section
Description
This is an editable field for the key name/description.
Keys, selected key
Keys, "key", Key param-
eters
Partitions
This section allows you to establish which partitions
the key can control.
Timers
This section allows you to associate a timer with the
key in order to filter the operability of the key on a
time basis.
Shortcuts
In this section it is possible to set the four shortcuts
(with any related parameter) that the key can activate
at a reader.
Each shortcut is associated with the lighting-up of a
specific reader LED:
•F1 - red LED
•F2 - blue LED
•F3 - green LED
• F4 - yellow LED
Patrol
The key will be a “Patrol” key.
Keys, selected key,
Options
Keys, "key", Change
key, Options,
Maintenance
The key will be able to block outputs associated with
alarm/tamper events for the time that it is held in the
vicinity of a reader.
Wireless
This option indicates whether the previously enrolled
key is a wireless key or not.
Use key short-
cuts only
If a key is held in the vicinity of a reader, only the key
shortcuts will be indicated and not the reader
shortcuts.
Use keyShortcuts
Total
disarming
disabled
If a key is held in the vicinity of a reader when some parti-
tions are armed, the Disarm option will be inhibited (all LEDs
Off).
DisarmNotAllowed
Valid key
A key is available that allows direct access to the
programming section of the access to the system
event via a valid key.
Keys, selected key
Events, Valid key