86 Monitoring the control panel
Centrali anti-intrusione
In this section, the monitoring window lists the parts of the sounder/flasher whose status is
represented by icons/LED:
Instead, the “Wireless monitoring” sub-section provides the
Start
button that starts a
monitoring on the variation of the signal transmitted by the device and background noise
detected over time.
21-7
Walk test
This section provides a quick and easy way of testing all the configured inputs.
After initializing the Walk test, all the operator need to do is walk through the protected
partitions and then check the detection capacity of the inputs via the system keypad or Prime/
STUDIO software application.
Via keypad
Type-in Code
(Installer)
, PROGRAMMING Walk test .
Access to this section opens the full list of configured zones on the keypad display.
As these input zones are violated by the operator carrying out the walk test, they will be
cleared from the list and the keypad will emit a long beep.
You can consider the outcome of test positive when there are no zones left on the list.
Via software
Click-on the
Monitoring
button on the menu bar, then go to the “Programming, Sounder/
flashers” section.
The list of zones and the
Start Walk test
button will be shown.
Once the test starts, the operator can walk through the entire area protected by the system
and verify the correctness of the detection capacity of the inputs by means of the information
reported in this section, marking the violated areas with a red dot and the time of the
violation.
The
Print Walk test
button allows the so0ftware to print the test results.
21-8
Monitoring the power supply
The software has a section for monitoring the power supplies, through LEDs with the relative
colours and values shown in the readings.
Via software
Click-on the
Monitoring
button on the menu bar, then go to the “Programming, Power”
section.
After clicking-on the
Start monitoring
button this section will show:
data relating to the power supplied to the control panel
•• primary power supply
•• power and secondary power supply
Table 21-4: Wireless sounder/flasher status LED
LED Status LED Status
Tamper
Green
Sounder/flasher not in tamper
status
Flasher active
Green
Visual signalling Off
Red
Sounder/flasher in tamper
status (open or dislodged)
Red
Visual signalling On
Antifoam
Green
Foam level below alarm
signalling threshold
STATUS LED
ON
Green
STATUS LED Off
Red
Foam level above alarm
signalling threshold
Red
STATUS LED On
Battery fault
Green
Battery charged
PRG LED ON
Green
PRG LED Off
Red
Battery charge low (below
40%)
Red
PRG LED On
Sounder
active
Green
Audible signalling Off
Signal recep-
tion level
This series of notches
represents the reception level
of the wireless signal of the
device as received by the Air2-
BS200 transceiver.
Red
Audible signalling On
Battery level
Percentage of the sounder/
flasher battery charge.