EasyManua.ls Logo

INIM Electronics Prime - Chapter 17 Default settings; Default settings

INIM Electronics Prime
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
74 Default settings
Centrali anti-intrusione
Chapter
17
Default settings
The operations necessary for the reset of the factory default data vary and can be carried out
by the installer through one of the means of access the installer has to the control panel:
•the
FACTORY
and
RESET
buttons on the control panel PCB
the keypad, via the installer menu
the Prime/STUDIO software
ATTENTION!
Reset of the factory default programming data deletes all the previously programmed
parameter settings.
Note
Reset of the factory default programming data does not cancel the connection of the control panel to the
Cloud.
Via PCB
1. Press and hold the
FACTORY
button on the motherboard.
2. Press and release the
RESET
button on the motherboard.
3. Release the
FACTORY
button.
Within 70 seconds the control panel will reset the parameters factory default values, enroll all
the peripherals currently on the I-BUS and, if at least one keypad is connected, will ask you to
select the Language.
Reset to factory default will not clear the events log.
Via keypad
Type in Code
(Installer)
, PROGRAMMING Factory settings
This section allows you to reset to default settings all the control panel parameters, auto-learn
zone balancing values, auto-enroll I-BUS peripherals and restore the event codes of
CONTACT-ID reporting format.
Following each of these operations, the control panel will ask for confirmation by pressing the
OK
button.
Via software
The Prime/STUDIO software program allows you to reset the control panel default values only
for the following parameters:
digital dialer parameters
“CCC” field of CONTACT-ID protocol of the zones
phone calls on activation and restoral
outputs on activation or restoral
message playback on keypads on activation or restoral
SIA protocol parameters
CONTINUE?OK=YES
Table 17-1: Reset operations
Parameter Software section Installer menu section
Full reset
If you select this option, the control panel will reset
all programming data to factory default settings.
Not available
Default settings,
Factory data
Learn zone balancing
If you select this option, the control panel will
gather and and save the balancing settings of all the
zones automatically (Patent Pending).
Not available
Learn zone bal.
Enroll peripherals
If you select this option, the control panel will
reconfigure the IBUS and enroll in the new
configuration all the peripherals that respond to the
auto-enroll peripheral command.
Not available
Autoenroll periph.

Table of Contents

Related product manuals