74 Default settings
Centrali anti-intrusione
Chapter
 17
Default settings
The operations necessary for the reset of the factory default data vary and can be carried out
by the installer through one of the means of access the installer has to the control panel:
•the 
FACTORY
 and 
RESET
 buttons on the control panel PCB
• the keypad, via the installer menu
• the Prime/STUDIO software
ATTENTION!
Reset of the factory default programming data deletes all the previously programmed
parameter settings.
Note
Reset of the factory default programming data does not cancel the connection of the control panel to the
Cloud.
Via PCB
1. Press and hold the 
FACTORY
 button on the motherboard.
2. Press and release the 
RESET
 button on the motherboard.
3. Release the 
FACTORY
 button.
Within 70 seconds the control panel will reset the parameters factory default values, enroll all
the peripherals currently on the I-BUS and, if at least one keypad is connected, will ask you to
select the Language.
Reset to factory default will not clear the events log.
Via keypad
Type in Code 
(Installer)
, PROGRAMMING Factory settings
This section allows you to reset to default settings all the control panel parameters, auto-learn
zone balancing values, auto-enroll I-BUS peripherals and restore the event codes of
CONTACT-ID reporting format.
Following each of these operations, the control panel will ask for confirmation by pressing the
OK
 button.
Via software
The Prime/STUDIO software program allows you to reset the control panel default values only
for the following parameters:
• digital dialer parameters
• “CCC” field of CONTACT-ID protocol of the zones
• phone calls on activation and restoral
• outputs on activation or restoral
• message playback on keypads on activation or restoral
• SIA protocol parameters
CONTINUE?OK=YES
Table 17-1: Reset operations
Parameter Software section Installer menu section
Full reset
If you select this option, the control panel will reset 
all programming data to factory default settings.
Not available
Default settings,
Factory data
Learn zone balancing
If you select this option, the control panel will 
gather and and save the balancing settings of all the 
zones automatically (Patent Pending).
Not available
Learn zone bal.
Enroll peripherals
If you select this option, the control panel will 
reconfigure the IBUS and enroll in the new 
configuration all the peripherals that respond to the 
auto-enroll peripheral command.
Not available
Autoenroll periph.