34 Programming terminals
Centrali anti-intrusione
6-1
Zones/Inputs
The terminal the zone is connected to must be configured as an “input”.
Via keypad
Type in Code
(Installer)
, PROGRAMMING Terminals,
select the terminal concerned configured as input
(“
I
”)
or
Type in Code
(Installer)
, PROGRAMMING Zones ,
select the zone concerned
Via software
To program the zone, select the
Terminals
button. The “Programming” section on the right
will show the graphic representation (map) of the terminals of the entire system.
Here, by double clicking on the terminal configured as a “zone” you enter programming.
or
Click-on the
Zones
button on the menu on the left, the "Programming" section will show a list
of all the available zones and their parameters. By selecting one of these items it is possible to
set the parameters of the single zone by clicking on the button.
Table 6-3: Zone parameters
Parameter Software section Installer menu section
Description
This is the editable label which identifies the zone. At
default all the zones assume the description of the
peripheral they refer to, followed by the respective
terminal.
Zones, selected zone
Zones, "zone"
Type
Dropdown box for the selection of the zone type:
Instant, Delayed, Viewable delayed, Route, 24hour,
Technological, Arm, Disarm, Switch, Follow, Patrol.
Balancing
Dropdown box for the selection of the balancing type
(the options vary in accordance with the zone type).
Normally open (NO), Normally closed (NC), Single
balancing, Double balancing, Double zone (without
EOL), Double zone (with EOL).
Detector type
Generic zone, Roller blind, Shock
Alarm cycles
Dropdown box for the selection of the number of
alarm cycles (between 1 and 14).
If you select “Unlimited”, the zone will operate as a
“repetitive” zone.
Wiring diagram
Button for to open a window showing the zone
connection mode.
Contact ID
Check box to indicate the Contact-ID code associated
with the zone for the occurrence or restoral of events
such as:
• Zone alarm
• Zone tamper
• Zone bypass
•Zone real-time
Wiring diagram
Button for to open a window showing the zone
connection mode.
Not available
Real-time
Section for the adjustment of zone detection
thresholds. The thresholds can be modified via the
number boxes or by using the bar which indicates the
levels by means of colours:
• yellow - tamper/short
•green - stand-by
• red - alarm
• orange - double zone with one zone in alarm
status and the other in stand-by status
Clocking-on the Real-time button makes a
connection with the zone which feeds back
information regarding the thresholds. The OK button
saves the changes which will be written during the
write phase.
Not available