Programming manual
Programming from the Control panel 29
4-5
Compliance 50131 grade 3
The Prime/STUDIO software provides a section for a configuration of the control panel that
complies with grade 3 of 50131 regulations.
However, total respect of the said regulations is obtained by appropriately setting also the
other options related to grade 2. For this purpose refer to
Chapter 19 Compliance with rules
in force
..
I-BUS fuse fault Yes Yes False key Yes No
Battery fault Yes Yes GSM fault Yes No
Mains failure Yes Yes Input undergoing programming Yes Yes
Expansion tamper Yes Yes Output fault Yes No
Keypad Tamper Yes Yes Low credit Yes No
Table 4-5: Preset events for the Cloud
Event
Communication to Cloud in case of
Event
Communication to Cloud in case of
Activation Restoral Activation Restoral
Table 4-6: Parameters for compliance
Parameter Software section Installer menu section
This section allows you to select which faults or events, other than zones in
alarm status, will be signalled as system security-risk conditions when the
partition arms.
Regulatory
compatibility
Forced arming
faults
Other parameters,
FaultForNotReady
Zone fuse fault
The zone protection fuse on the control panel is not
operational (blown)
Zone fuse fault
I-BUS fuse fault
The I-BUS protection fuse is not operational (blown)
IBUS fuse fault
Low battery
The backup battery is low
Low battery
Mains failure
The primary power supply 230V~ fails
Mains failure
Telephone line down
The land line is not working
Tel. line down
Jamming
Wireless interference detected
Jamming
Low battery wireless
The battery of a least one wireless detector must be
replaced
Low battery WLS
Wireless zone loss
Loss of at least one wireless detector has been
signalled (supervisory time expired)
WLS zone loss
Loss or tamper ongo-
ing
This warning groups together the following events:
Control panel open
Dislodged panel
Expansion tamper
Keypad Tamper
Reader Tamper
Sounder flasher tamper
•Nexus tamper
Expansion loss
Keypad Loss
•Reader Loss
Sound.flash.Loss
•Nexus loss
LossTamp.ongoing
GSM BUS fault
Nexus device fault
Nexus fault
Faults on zones
Violation has occurred on one or more zones with the
“Fault zone” option enabled.
Faults on zones
Faults on sounder/
flashers
Fault present on one of the sounder/flashers
Faults on sounder/
flashers
Contaminated smoke
sensor
The smoke chamber of at least one of the Air2-FD100
smoke detectors is contaminated by dirt or dust.
Not available
Detector dusty
General power-supply
faults
Fault present on the power supply or one of the power
sources
Not available
Power faults
Keypad faults
Fault present on one of the keypads Not available
Keypad faults
IP connection lost
The IP connectivity test is enabled and the test has
failed
Not available
IP conn. lost