40 Programming terminals
Centrali anti-intrusione
the “controlled output” attribute. By selecting one of these items it is possible to set the
parameters of the single zone by clicking on the button.
6-5
Wireless terminals
The parameters necessary for enrolling and programming wireless terminals will be displayed
only when the terminal has been previously defined as “Wireless”.
These parameters vary depending on the type of wireless device to be configured.
6-5-1
Enrolling devices
1. Go to the expansion board field and then to the terminal concerned.
2. Configure the terminal as “Wireless”:
Via keypad
Type in Code
(Installer)
, PROGRAMMING Terminals,
select the terminal concerned
Press the number button ; the word “Wireless” will appear on the last line of the display
(pressing the button again will disable the wireless attribute on the terminal).
Via software
Right-click and select “Wireless” (the PCB image will change to colour only after a successful
enrollment procedure of the relative devices).
Note
If a terminal on the expansion board is configured as “wireless”, all the remaining terminals must be
configured as “wireless” terminals.
3. Enrolling the terminal:
Via keypad
Type in Code
(Installer)
, PROGRAMMING Terminals,
select the terminal concerned
, Wireless, En-
roll device
Enroll the terminal by selecting the type.
Via software
Double-clicking on the configured terminal will open a window where you can program the
zone. The lower part of the window shows the “Wireless section”, right-click and select the
“Wireless” option. Select the type of device, in the “Type” field, then start the guided enrolling
process by clicking-on the “Enroll” button.
Table 6-8: Wireless terminal types
Air2 device Single/Double Via software Via keypad
IR100 Single
Infrared
Infrared detectors
MC300
Reed contact Single
Magnetic contact
Magnetic Contact
TerminalT1 Single
Terminal 1 Magnetic contact
Terminal T1 MC
TerminalT2 Single
Terminal 2 Magnetic contact
Terminal T2 MC
FD100 Single
Smoke detector
Smoke detector
XIR200W Single
Passive infrared detector
Single T detector
OTT100W Single
Outdoor terminal
OutdoorDetector
ODI100W Single
Outdoor terminal
OutdoorDetector
UT100 Single
Outdoor terminal
OutdoorDetector