Programming manual
Programming terminals 41
4. For Air2 devices press the
ENROLL
button.
5. If the device to be enrolled is an output connected to a terminal of any device with an
Air2-MC300 output terminal, you must enable the “Broadcast RF” zone option (refer to
Table 6-9: Wireless parameters
).
Once done, you must step back to the configuration of the terminal and configure it as
an “OUTPUT”.
Note
The “Broadcast RF” option must be enabled for each terminal of the Air2-MC300 device concerned.
6. Enroll all remote controls in the same way as you would enroll keys, and select as the
reader the one with the same address as the expansion.
7. Set the parameters of the zones, outputs and keypads.
6-5-2
Programming wireless terminals
MC200 Double
MC200 magnetic contact
Cont.Magn.MC200
DT200T
Curtain detector Double
Curtain detector
Curtain detector
Detector direction Double
Directional detector
Curtain direction
XDT200W Double
Dual technology detector
Dual T detector
Table 6-8: Wireless terminal types
Table 6-9: Wireless parameters
Parameter Software section Installer menu section
Enroll
This section allows you to enroll a wireless detector
which has not yet been enrolled on the terminal
concerned.
Selected terminal,
Wireless
Terminals, "terminal",
Wireless
Enroll device
Type
Type of device to be enrolled (Table 6-8: Wireless
terminal types).
Remove
Section to delete from the terminal in question.a
previously enrolled wireless detector.
Delete device
Sensitivity
The “Wireless” section contains the parameters for
adjustment of the detector sensitivity of the
previously enrolled devices and their functions.
These parameters vary depending on the type of
wireless terminal to be configured (refer to Table 6-8:
Wireless terminal types and Table 6-10: Wireless
detector sensitivity).
Terminal type
Tamper on
unused reed
relays
Detects tamper on the Air2-MC300 magnetic-contact
when both reeds are in stand-by status.
Selected terminal,
Wireless, Options
Terminals, "terminal",
Options,
TampReed/FollPir
Disable detector
when partition is
disarmed
In order to increase battery life, the PIR detector will
deactivate when the partitions it belongs to are
disarmed and will only activate when the partitions it
belongs to arm.
Deactivated detectors do not generate alarms. When
the partitions arm, there may be a delay of up to 3
minutes before the detector receives the activation
command.
Use detector LED
The red LED on the device provides visual signalling
of alarm or tamper conditions on the device itself.
This option will be enabled on all the terminals of the
Air2 device.
Use sensor LED
Broadcast RF
This option assures the activation/deactivation of the
output within 2 seconds of the control panel
command. Valid only for terminals T1 and T2 of Air2-
MC300 configured as outputs.
Broadcast RF
Bypass tamper
If this option is disabled, open/dislodgement tamper
on Air2 devices will not generate the respective
events.
DisableTamperWLS WLS