60 Programming events
Centrali anti-intrusione
12-2
Maintenance of events
12-3
Output scenarios
It is possible, exclusively via the Prime/STUDIO software, to associate the activation of an
output scenario with the activation and restoral of each event.
The Prime control panel provides 50 output scenarios, each with a maximum of 10 outputs.
Programming occurs in two phases: the first is the definition of the scenarios, the second is
the assignment to the activation and restoral of the event.
Via software
Click-on the
Events
button on the menu on the left, the “Programming” section on the right
will show the "Output scenarios".
Table 12-5: Shortcut on event
Shortcuts Function Parameter
Activate scenario
Shortcut that activates the scenario selected in the check box alongside. One of the 30 shortcuts available
Activate output
Shortcut that activates the scenario selected in the check box alongside. One of the configured outputs
Deactivate output
Zone bypass
Shortcut that deactivates/activates the zone selected in the check box along-
side.
One of the configured zones
Unbypass zone
Disable code
Shortcut that deactivates/activates the code selected in the check box along-
side.
One of the available codes
Enable code
Disable key
Shortcut that deactivates/activates the key selected in the check box along-
side.
One of the available keys
Enable key
Activate thermostat
Shortcut that activates the keypad thermostat in the operating mode selected
in the check box alongside.
One of the keypads available
Thermostat operating mode
Deactivate thermostat
Shortcut that deactivates the keypad thermostat selected in the check box
alongside.
One of the keypads available
Dimmer up
Shortcut that increases/decreases by 5% the value of the voltage supplied to
the dimmer output selected in the check box alongside.
One of the outputs configured as
dimmer
Dimmer down
Delete alarm memory
Shortcut that deactivates the outputs relative to zone/partition alarm and
tamper events and deletes the partition and system alarm and tamper mem-
ories.
This shortcut operates on the partitions selected for the scenario.
One of the 30 shortcuts available
Table 12-6: Single event parameters
Parameter Software section Installer menu section
Reset CONTACT-ID
default
Button to reset the default values of the digital
communicator for all the events.
Event
maintenance
Default settings
CONTACTIDDefault
Delete activation/
restoral outputs
The sections with a Delete button allow you to
delete all the outputs associated with the activation/
restore actions of each event.
Not available
Delete activation/
restoral calls
The sections with a Delete button allow you to
delete all the telephone calls associated with the
activation/restore actions of each event.
Not available
Delete voice message
playbacks on activa-
tion/reset
The sections with a Delete button allow you to
delete all the voice message on keypad playbacks
associated with the activation/restore actions of
each event.
Not available
Reset SIA protocols to
default
This section provides a Reset default button that
resets the default settings of SIA protocol codes for
all the events.
Default settings
SIA defaults
Delete shortcuts on
event
This section provides a Delete Shortcuts button
that cancels the “Shortcut on event” parameters on
all the events.
Not available