Programming manual
Programming keys 51
Note
The "Use only key shortcut" and “Total disarm disabled” options have no effect for wireless keyfobs.
Table 10-2: Readers - LED visualization
LED On sequence
Option: Use key shortcut only
enabled disabled
1
Red LED On Key shortcut F1 shortcut associated with the red LED on the reader
2
Blue LED On Key shortcut F2 shortcut associated with the blue LED on the reader
3
Green LED On Key shortcut F3
shortcut associated with the green LED on the
reader
4
Yellow LED On Key shortcut F4
shortcut associated with the yellow LED on the
reader
5
All LEDs On This sequence does not occur Key shortcut F1
6
All LEDs Off
Option: Total disarming disabled
enabled disabled
No request to arm all the partitions common to both
the key and reader.
Request to disarm all the partitions common to both
the key and reader.