18 Programming peripherals
Centrali anti-intrusione
Table 3-8: Ivy-B hardwired sounder/flasher parameters
Parameter Software section
Real-time
Click-on the Real-time option to display the following real-time features of the
sounder/flasher:
Configured
sounder/flasher,
selected sounder/
flasher, Real-time
Battery voltage
Voltage of the internal battery of the sounder/flasher.
Line voltage
Voltage detected on terminals 1 and 2 of the
sounder/flasher.
Temperature
Internal temperature of the sounder/flasher read by
the thermal probe.
Foam left/right
Values detected by the foam protection sensor (left/
right).
Tamper
Value read by the open-panel sensor
Sounder/
flasher parame-
ters
Read sounder/flasher
Clicking-on the Read sounder/flasher and Write
sounder/flasher buttons will allow you to set the
parameters of the sounder/flasher.
Configured
sounder/flashers,
selected sounder/
flasher, Sounder/
flasher parameters
Write sounder/flasher
Default
Button to reset the factory default data
I-BUS loss signal delay
This is the time the sounder/flasher must wait before
signalling the loss of the I-BUS signal (expressed in
minutes).
Version
This is the firmware version of the sounder/flasher
board.
Sounderflasher address
Dropdown box for the selection of the BUS address of
the sounderflasher.
I-BUS loss
Activation of LED input
Power failure
Open cover signalling
Foam tamper signalling
Blow-torch tamper signalling
Horn fault
Battery status
The check boxes in this section allow you associate
one or more signals to each of the sounder/flasher
events.
The available signals are aligned with the wording of
each event:
• FAULT output
•TAMPER output
• STATUS LED
•PRG LED
•Flasher
• Sounder
Audible signalling
Horn tone selection
Maximum audible signal time
This is the maximum time the sounder is allowed to
emit the audible signal, however, the visual signals
will continue until the device is reset.
STATUS LED ON
If this option is enabled, the STATUS LED will go On
solid.
Flashes/minute
Selects the flash rate on the flasher.
Enable flasher LED input
Option to allow blinking on the STATUS LED and PRG
LED activated by the LED input.
Monitor IBUS
If this option is enabled, the BUS will be monitored
for one minute after each control panel reset
operation and its status will be signalled on the PRG
LED as follows:
• On solid - BUS not connected
• 1 flash per second - BUS connected but sounder/
flasher not enrolled
• 2 flashes per second - BUS connected and
sounderflasher enrolled
TAMPER and FAULT outputs
This option allows you to select the type of contact
(normally open or closed) of outputs during stand-by
status.
Temperature
compensation
If the internal temperature of the sounder/flasher indicated in the “Real-time” section
is incorrect, you can use this section to set the real temperature value and correct the
parameter by means of the Compensation button.
Configured
sounder/flasher,
selected sounder/
flasher,
Temperature
compensation