26 Programming from the Control panel
Centrali anti-intrusione
“Cloud Mode”
If enabled, this option will apply a preset of some of
the control panel parameters that would otherwise
have to be programmed individually for connection to
the Inim Cloud service.
Refer to paragraph 4-4 “Cloud mode” preset.
Not available
Date/Time
Editable field for the system date and time.
User functions, Set
date/time
Set local time
This button sets the local time of the PC in use. Not available
Write on control
panel
This button writes the local time of the PC on the
control panel.
Not available
Table 4-2: Control panel definition
Table 4-3: Control panel options
Parameter Software section Installer menu section
Restart
monostable out-
puts
If activated, each event which activates a monostable
output refreshes the programmed “Monostable time”.
Control panel
parameters
Parameters,
RefreshMnstblOut
Does not arm if
any of the zones
are not ready
The control panel will not arm the partition if it
detects any zones that are not in stand-by status.
If, amongst the zones not in standby status, there are
zones configured as “Autobypassable” or “No arm if
not ready” (refer to paragraph 6-1 Zones/Inputs)
they will be indicated on the keypad. If the user still
arms the system, these zones will be inhibited
automatically and the partitions they belong to will be
armed.
OpenZonesArmLock
Bypass tamper
in the event of
bypassed zones
If a zone is bypassed (disabled), it will also be unable
to generate terminal tamper.
BypassAlsoTamper
Prevents the
deletion of tam-
per memory by
user code
No user will be allowed to delete of the following
events:
• terminal tamper
• control panel open-tamper
• control panel dislodgement-tamper
•peripheral tamper
• peripheral loss
•false key
NoUserTamp.reset
Instant reset of
wireless mag-
netic contact
If this option is enabled, reset of the magnetic reed
sensor of wireless detectors will be signalled instantly
(otherwise signalling has a maximum delay of 10
seconds).
Instant restoral
Lock installer
code
If this option is enabled, all the control panel
parameters with the exception of the installer PIN will
reset to the factory default settings after reset.
LockInstall.Code
Automatic Day-
light Saving
Time (DST)
The control panel clock will go back automatically one
hour at 03:00 the first Sunday in October, and it will
go forward automatically one hour at 02:00 the last
Sunday in March.
DayLightSav.time
Use fault output
for smoke sen-
sor contamina-
tion
Enables management of the “Contaminated smoke
detector” event.
The “Output fault” and “Detector dusty” events share
the same actions. Therefore, if either of these events
occur, the system will send the calls and activate the
outputs associated with the “Output fault” event.
The events log provides the proper distinction
between these two events:
• in the event of an “Output fault”, the system will
provide the description of the output in fault
status
• in the event of an “Detector dusty”, the system
will provide the description of the detector that
generated the event
Dust event enab.
Maintenance
You can start the maintenance session from the
keypad without need of opening the control panel or
moving the jumper. After exiting the Installer menu,
you can operate on the system in the same way as
when the control panel is placed in maintenance
mode by means of the jumper.
You must disable this option if you wish to put the
control panel in “RUN” mode.
Maintenance
Check horn
The control panel will generate a “Sounder/flasher
tamper” event when the passive horn disconnects
from the relay (wire cutting tamper).
Tamper siren