100 Options and programming methods
Anti-intrusion control panels
Do not increase the “VolumeTel. In” parameter excessively, as an excessive value
may cause incorrect interpretation of DTMF tones.
If the volume of the telephone messages is low, increase the “Volume Tel.voice” (in
small steps of 1 or 2 units) and verify the effect. An excessive value of the “Volume
Tel.voice.” parameter may cause incorrect interpretation of DTMF tones.
In most cases, the value of the “Volume Tel.voice” parameter is between 15 and 25,
whereas, the value of the “VolumeTel. In.” parameter is between 20 and 30.
If there is a SmartLinkAdv GSM interface, it is possible to adjust the values of incoming
and of the output volume parameters of the SmartLinkAdv.
Note
Any changes to the value of the SmartLinkAdv incoming volume parameter come into effect
almost 2 minutes after the setting change, therefore, you must allow this time to pass before
verifying the effect.
7-28
Activating outputs without
authentication
It is possible to programme a certain number of outputs which can be viewed and
activated at the keypad without authentication (i.e. without entering a user code).
Access to these outputs depends on the type of keypad in use:
for keypads with keys, you must activate the “Output control” shortcut (shortcut n.
21: ) associated with one of the , ...,
for Alien keypads, you must access the “Commands” section by tapping the
button, then the “Domotics” section.
The outputs that can be activated from a keypad with the “NNN” address will be those
associated with a specific user code.
The keypad, code and relative outputs must be programmed in accordance with the
following procedure:
Via Keypad
1. Access the section of the Installer menu for the programming of the “NNN” key-
pad you wish to associate with the outputs:
Type-in Code (Installer) , PROGRAMMING Keypads ,
Select peripheral , Keypad “NNN”
2. Access the “F1/4KeyShortcuts” section and select a function key
3. Access the “Type” section and associate the selected function key with the “Out-
put control” shortcut.
4. DO NOT ENABLE the “Requires code” option for the shortcut associated with the
function key undergoing programming.
5. Go back to the installer menu and access the “Codes” section.
6. Select the user code shown in the table in accordance with the control panel
model undergoing programming:
7. Access programming of the selected code, at the “Assigned outputs” section.
8. Use keys and to select the outputs from those available on the list.
Table 7-22:
User code number
Keypad number
SmartLiving Model
505, 515 1050 10100
001 026 041 086
002 027 042 087
003 028 043 088
004 029 044 089
005 030 045 090
006 / 046 091
007 / 047 092
008 / 048 093
009 / 049 094
010 / 050 095
011 / 096
012 / 097
013 / 098
014 / 099
015 / 100
Type
ZoneBypass menu
Voice memo
Output control
KEYP. NNN
Type
Options
KEYP. NNN
Partitions
Options
F1/4KeyShortcuts
F1/4KeyShortcuts
F1
F2
F3

Table of Contents

Other manuals for INIM Electronics SmartLiving 10100L

Related product manuals