96 Options and programming methods
Anti-intrusion control panels
Via PC
The SmartLeague software programme allows you to reset the control panel default
values only for the following parameters relative to the programming of events:
• digital dialer parameters
• “CCC” field of CONTACT-ID protocol of the zones
• phone calls on activation and restoral
• outputs on activation or restoral
• message playback on keypads on activation or restoral
• SIA protocol parameters
7-26
User functions
This section describes the functions the installer has in common with the user.
Via Keypad
1. Access the “User functions” section:
Type-in Code
(Installer)
, PROGRAMMING User functions .
2. Use keys and to select the function then press :
Activations
This section provides information regarding the “Cloud enrollment” option which allows
the SmartLiving panel to access INIM Electronics cloud service.
View
• Events log - allows you to view all the events saved to the log.
• Alarms log - allows you to view all the events relating to zone/partition alarm and
tamper saved to the log.
• Faults log - allows you to view all the fault events saved to the log.
• Arm/Disarm ops. - allows you to view all the arm/disarm operations saved to the
log.
Use key or to scroll the chronological events list. For some events, key
allows you to view the partitions details. For example, the details of an “Arm” command
will show the code and keypad concerned and, if you press , the list of partitions
involved.
• Nexus status - allows you to view (on the display) the following parameters of the
Nexus device:
1° line: GSM network provider (Vodafone, etc.), on the left side and BUS connections
on the right side of the string:
- if nothing appears, it means that the Nexus/G is connected to the BUS
- if the letter “G” appears, it means that the Nexus/G is connected to the BUS
and that the GPRS service is available
- if the letter “
C
” appears, it means that the Nexus/G is connected to the BUS
and that a teleservice request (TCP connection) or SIA-IP event report is being
sent
- if “
--
” appears, it means that the Nexus is connected to the BUS
2° line: GSM signal reception (value between 1 and 100)
3° line: balance, at the last operation (expressed in the local currency)
4° line: faults present - access the “View-Faults” section for details.
• System voltage - allows you to view the voltage the system uses.
• Zone status - allows you to view the status of all the zones. Use keys and
to scroll the list of accessible zones. The display shows the following zone
parameters:
1° line: zone description
2° line: zone status (“Standby”, “Alarm”, “Short”, “Tamper”), its activation status (“un-
bypassed” - capable of generating alarms, or “bypassed” - incapable of gen-
erating alarms)
Table 7-19:
Factory default settings - via SmartLeague software programme
Option Part of the system Template/section
CONTACTIDDefault
SmartLiving System - Events Programming - Maintenance events
CONT-ID enumer.
SmartLiving System - Terminals
Programming - “Rename the CCC in sequential
mode”
DeletePrg.events
SmartLiving System - Events Programming - Maintenance events
Installer Code
18:23 3/30/2017
KEYP. 001
VIEW
Events log
Alarms log
Faults log
PROGRAMMING
Messages
Default settings
User functions
User functions
View
Outputs ON/OFF
Set date/time