Installation and programming manual
Combination of outputs triggered by events 123
Appendix F
COMBINATION OF OUTPUTS
TRIGGERED BY EVENTS
This appendix shows the event-generated actions (activations/deactivations) of the
outputs programmed in the “Outputs” and “Other outputs” sections combined with the
“SirenSound types” of the sounderflashers on the BUS.
Tabella F-1:
Output typology
Symbol/Initials Description
TM
Output on terminal/Relay/OC1/OC2 - monostable
TB
Output on terminal/Relay/OC1/OC2 - bistable
SM
Sounderflasher output with limited flasher time
SB
Sounderflasher output with unlimited flasher time
Tabella F-2:
Functioning and deactivation of the outputs
Symbol/Initials Description
A
These outputs will deactivate if a Stop alarm, Reset partition or Disarm operation is carried out while the monostable time
of the main output is running.
B
These outputs will deactivate only when the event clears after expiry of the monostable time of the main output.
C
These outputs, due to the continuous flasher function, will not deactivate automatically.
In order to deactivate the SB flashers of the sounderflasher after expiry of the monostable time applied to the main out-
put, you must:
trigger an event which applies a Stop pattern to the SB flashers
reset the partition
D
These outputs will deactivate only when the event clears.
E
These outputs will deactivate if, when an event is active, a Stop alarm operation, reset or disarm partition command oper-
ation is carried out.
F
These outputs, due to the continuous flasher function, will not deactivate automatically. In order to deactivate the SB
flashers of the device on termination of the event, you must:
trigger an event which applies a Stop pattern to the SB flashers
reset the partition
G
These outputs will deactivate when the respective monostable time expires
Ta b el la F- 3 :
Output combinations
Event groups
Principal output Other outputs
TM TB SM SB TM TB SM SB
Zone Alarm
terminal tamper
partition alarm
partition tamper
A G A G A B A G A C
D E E G D G E G F
A G A G A B A G A C
FE GD GE GF
Control panel open
Dislodged panel
Expansion tamper/loss
Keypad tamper/loss
Reader tamper/loss
Sounderflasher tamper/loss
Jamming
Wireless zone loss
Telephone line down
A G A G A D A G A C
D E E G D G E G C
A G A G A B A G A C
FE GD GE GC
other events
GGBGC
DGDGF
GGBGC
FGCGC