6. Enroll the terminal as “Terminal T1 CM” or “Terminal T2 CM”.
7. Press the “ENROLL” button on the Air2-MC100 device.
8. Enable the “Broadcast RF” option as follows:
Type in Code
(Installer)
, PROGRAMMING Zones ,
select the zone
, Options ,
BroadcastRF.
Note
The “Broadcast RF” option must be enabled for each terminal of the Air2-MC100 device
concerned.
9. Go back to step 1 and configure the terminal as an output ( ).
10. Press to access the output parameters programming section (description,
options, etc.).
Press in correspondence with any terminal, provided that it is not an UNUSED
terminal, to access the parameter programming section of the type of terminal
selected, whether it is a zone or an output (refer to paragraph 7-7 Zones or paragraph
7-8 Outputs).
Via PC
Select “SmartLiving System - Terminals” from the tree menu on the left, then go to the
“Parameters settings” template on the right:
All the terminals will be shown on the respective page. You must configure the terminal
graphically using the mouse, as follows:
1. Point to the terminal you require.
2. Right click on the mouse and select the required type.
3. Double click to set the options for the terminal.
4. Position the mouse on the programming field instead of on the specific terminal
to configure all the terminals in the same way.
If the terminal is configured as “Zone” (=INPUT) or “Double” (=DOUBLE ZONE), it will
appear in the Zone programming section (paragraph 7-7 Zones). If the terminal is
configured as an “Outputs” (=OUTPUT) or “I/O” (= TWO WAY), it will appear in the
Outputs programming section (refer to paragraph 7-8 Zones).
7-7
Zones
This programming section deals with all the zone parameters.
Via Keypad
1. Access the “Programming Zones” section.
Type-in Code
(Installer PIN)
, PROGRAMMING Zones .
2. Using keys and , select the zone then press .
Description
This is the editable label which identifies the zone. At default all the zones assume the
description of the peripheral they refer to, followed by the respective terminal.
1° line: default description
2° line: current description
3° line: description being edited
4° line: characters available
For example, the default description “Expansion 04 T03 corresponds to the zone located
on terminal T3 of Expansion n. The default descriptions “Panel T05” and “Panel T05D”
correspond to the two zones located on terminal T5 of the control panel, configured as
“Double Zone”.
Partitions
These are the partitions the zone belongs to. A zone configured as “Automation” cannot
be assigned to any partition.
Use and to enable or disable the selected partition.
Type
Use and to select the type of zone, then press . The available Types are
(refer to Appendix A, Technical terminology and Glossary):