66 Options and programming methods
Anti-intrusion control panels
Instant
Delayed
Delayed unhidden
Route
24 hour
Automation
Armed in Away mode
Disarm
Switch
OnArm/OffDisarm
Patrol
For “Arm”, “Disarm”, “Switch”, “OnArm/OffDisarm” “Follow” and “Patrol” zones, refer to
Appendix A, Technical terminology and Glossary, Command Zones.
“Delayed” and “Delayed unhidden” zones are delayed during entry and exit phases, in
accordance with the respective “Entry Time” and “Exit Time” settings (refer to
paragraph 7-13 Partitions). A “Delayed unhidden” zone behave as follows:
•• if violated when the system is disarmed, it will switch Off the blue LED on the
keypad
•• if the “View open zones” option is enabled, it will be shown on the keypad
•• it will not generate “Partition not ready” events
•• On arming from a keypad, the zone will appear as a violated zone but, when the
arming operation is confirmed, will behave as a delayed zone and will not
generate an alarm.
•• if the “OpenZonesArmLock” option is enabled and the zone is violated, it will
appear as a violated zone but, when the arming operation is confirmed, will
behave as a delayed zone and will not generate an alarm.
•• if the “OpenZonesArmLock” option is enabled, the zone is violated and instant
arming is required, the zone will appear as a violated zone and when the partition
arming operation is confirmed, the partitions the zone belongs to will not be
armed.
Options
The available options (refer to Appendix A, Technical terminology and Glossary) must
be enabled/disabled by keys and :
Interior
Auto-bypassable
Unbypassable
Chime
Test
TampReed/FollPir
Broadcast RF
Use sensor LED
The last three options apply to “Wireless” zones only, a full description of which follows.
No-Unbypassable If this option is enabled, the zone will operate as an “Auto-
bypassable” zone, with the difference that it will be automatically unbypassed when
the partition next disarms.
Office
Description
Partitions
Type
PROGRAMMING
Panel options
Terminals
Zones
Zones
Bedroom
Panel T02
Panel T03
Panel T01
Bedroom
Bedroom Jenny_
m oMNO6ò
n
Table 7-3:
Wireless zones options
Option If enabled If disabled
TampReed/FollPir
Air2-IR100
- in order to increase battery life, the infrared
sensor will deactivate when the partitions it belongs to are
disarmed and will only activate when the partitions it
belongs to arm.
Deactivated detectors do not generate alarms. When the
partitions arm, there may be a delay of up to 3 minutes
before the detector receives the activation command.
Air2-MC100/MC200
- detects magnetic-contact tamper
when both reeds are in standby status.
Air2-IR100
- the PIR detector will be active at all
times.
Air2-MC100/MC200
- tamper on the magnetic
contact will not be detected.
Broadcast RF
This option must be enabled when the zone and one of the Air2-
MC100 terminals (“T1” or “T2”) is configured as an “output”.
Assures the activation/deactivation of the output within two
seconds of the control panel command.
The activation/deactivation of a “wireless” output
occurs within 6 minutes of the control panel command.
Use sensor LED
The red LED of Air2-IR100 and Air2-MC100/MC200 devices sig-
nal alarm or tamper on the device.
Note
This option will be enabled on all the terminals of the Air2-
MC100.
The red LED of Air2-IR100 and Air2-MC100/MC200 will
be “Off” at all times.