14 The control panel and peripherals
Anti-intrusion control panels
2-1-3
ATS Categories
SmartLiving control panels used alone or together with any of the following described
optional devices constitutes an SPT (Supervised Premises Transceiver) which can be
used to create an ATS (Alarm transmission System) as defined in EN 50136-1 and EN
50136-2 standards.
The following table shows the maximum ATS categories achievable with the SPT
configurations and main communication channel in use, together with the respective
parameters.
2-1-4
Events log memory
The control panel events are saved to a non-volatile semiconductor-memory which
retains data without the need of power.
The electrical characteristics of semiconductor devices diminish over time. However, a
minimum period of 40 years data retention is guaranteed.
2-1-5
I-BUS interconnections
SmartLiving control panels are equipped with a 4-wire BUS for peripheral
interconnections (2 power-supply wire and 2 data exchange wires, refer to paragraph
3-2-1 The I-BUS line wiring).
The intellectual property rights regarding the electrical, structural and protocol features
of the BUS are the sole property of INIM Electronics s.r.l.
The I-BUS is not a RS485 differential BUS.
2-2
Environmental Conditions
SmartLiving control panels must not be installed outdoors and are suitable for operating
under the following conditions:
• Temperature: from -10° to +40°C
• Maximum humidity: 75% (without condensation)
• Environmental class:II
The Joy/GR, Joy/MAX, Aria/HG, nCode/G, Concept/G, Alien/S, Alien/G, IB100, FLEX5,
Nexus and nBy/X peripheral devices are for indoor installation only and operate best
under the following environmental conditions:
• Temperature: from -10° to +40°C
• Maximum humidity: 75% (without condensation)
• Environmental class:II
Table 2-11:
ATS categories based on configurations
SPT Configurations
SPT primary network
interface
ATS Categories
SmartLiving
intrusion
control
panels
Nexus Nexus/G SmartLAN/G
SmartLAN/
SI
Single Path
(SP)
Dual Path
(DP)
X
PSTN 2 /
XX
PSTN or GSM 2 2
XX
GSM/GPRS 6 2
XX
Internet
62
XX
62
XXX
Internet or GSM/GPRS
64
XXX
64
Table 2-12:
ATS Parameters
ATS Categories
Transmission time
Time relation
Replacement
security
Information
security
Operating
mode
Classification
Maximum
values
Single Path
2 D2 (60s) M2 (120s) T2 (25h) S0 I0
Pass-through
6 D4 (10s) M4 (20s) T6 (20s) S2 I3
Dual Path
2 D3 (20s) M3 (60s) T3a (30min) S0 I0
4 D4 (10s) M4 (20s) T5 (90s) S2 I3