58 Options and programming methods
Anti-intrusion control panels
Chapter 7
OPTIONS AND
PROGRAMMING METHODS
7-1
Introduction
The options, functions and values of the SmartLiving control panel must be programmed
by qualified persons only. The SmartLiving control panel is programmed at the factory
with almost ready-to-go settings (“default settings”) which require only minor changes
during the system customization phase.
For example, all the zones, keypads and readers are assigned to (belong to) partition 1,
alarm and tamper events related to partition 1 activate the relay output which is
monostable set at 3 minutes (Monostable time = 3 minutes), etc.
All the parameters and programming data can be input via keypad or computer
(equipped with the SmartLeague software programme) with the following limitations:
• From the keypad you cannot program:
•• Timer exceptions
•• Input calibration
•• Sounderflasher tone
•• BUS speed
•• Description of the “Emergency keys”
•• Parameters relating to the SmartLAN board
•• Parameters relating to the Nexus GSM dialer
•• Parameters relating to the I-BUS Ivy-B
•• Programmable events
•• Shortcut on event
•• Output scenarios
•• Configuration of cameras
•• Configuration of graphic maps
• Via the SmartLeague software you cannot program:
•• DTMF sensitivity
•• The second Installer code
•• The Installer code PINs
•• The shortcut descriptions
The following chapter describes the programming flow of the system data in the order it
appears in the Installer menu on the keypad. The description of both programming
methods (from keypad; via PC) are provided.
7-2
Accessing the Installer menu
If you wish to program the system via the installer menu from a keypad and thus
upload/download the control panel parameters, you must:
1. Disarm all the control panel partitions.
2. Type-in a valid PIN (installer code) on the keypad then press .
If an Alien keypad is being used, access the “Settings” section by tapping the
button, type in the user code and access the “Installer section”, then enter
the Installer code.
The PIN is “9999” at default.
3. The system will allow access to installer menu only after the entry of a valid PIN.
Once access to the installer menu is achieved, the system will: