Installation and programming manual
Installation 43
3-5-4
Double-Zone balancing
Double zones without EOL resistor can discriminate 5 conditions on the
entire terminal:
• standby on both zones
• alarm on zone 1 and standby on zone 2
• alarm on zone 2 and standby on zone 1
•alarm on both zones
• tamper (wire cutting)
For each of these, the control panel reads different resistance values on
the terminal, expressed below in Ohm.
3-5-5
Double Zone balancing with EOL
Double zones with EOL resistors can discriminate 6 conditions on the
entire terminal:
• standby on both zones
• alarm on zone 1 and standby on zone 2
• alarm on zone 2 and standby on zone 1
•alarm on both zones
• tamper (wire cutting)
• tamper (short-circuit)
For each of these, the control panel reads different resistance values on
the terminal, expressed below in Ohm.
3-6
Wiring and balancing rollerblind/
shock sensors
It is possible to choose between two types of balancing for Rollerblind and Shock
sensors:
• Normally closed (N.C.)
• Single balancing (NC with EOL)
The following table compares the protection level of rollerblind/shock sensors using the
two balancing options provided by the control panel.
Ohm
Zone 1 Zone 2
(double)
> 3900 + 6800 tamper
3900 + 6800 alarm alarm
6800 standby alarm
3900 alarm standby
0 standby standby
Alarm
+12V GND
Tamper
3K9Ohm
1/4W
6K8Ohm
1/4W
Zone 1
Zone 2
Ohm
Zone 1 Zone 2
(double)
> 2 x 3900 + 6800 tamper (wire cutting)
> 2 x 3900 + 6800 alarm alarm
3900 + 6800 standby alarm
2 x 3900 alarm standby
3900 standby standby
0 tamper (short-circuit)
Alarm
+12V GND
Tamper