38 Installation
Anti-intrusion control panels
5. Install the microswitch as shown in the previous figure, so that the switch lever is
compressed. If an unauthorized attempt to dismantle the nBy/X reader occurs,
the lever will expand in order to open the contact which triggers instant alarms
on the 24H terminal.
Note
This wiring method can be applied in most situations, however, it is only a point of reference. In
order to ensure proper protection, you must always take in to account the specific mechanical
and electrical conditions of the device you are working on.
ATTENTION!
In order to avoid malfunction, it is advisable not to install nBy/X readers onto metal
plates.
3-2-10
Installing the Nexus
In order to allow this device to function properly, you must install it in a safe, dry place
which provides the best possible GSM reception.
ATTENTION!
Disable the SIM card PIN.
1. Ensure that the Nexus is not powered-up.
2. Insert the SIM card into its housing (refer to Table 2-36: Nexus - description of
parts, E).
3. Install the antenna and connect it to the respective input (refer to Table 2-36:
Nexus - description of parts, B).
4. Connect the BUS to the terminal board (refer to Table 2-36: Nexus - description
of parts, A).
3-3
Addressing the peripherals
In order to allow the control panel to identify the peripherals distinctly, you must assign
a different address to each device. However, you can assign the same address to two
devices which belong to different categories (e.g. a Flex5 expansion and a JOY keypad)
as, in this case, the control panels will see them as two distinct devices.
You must not exceed the maximum number of addresses allowed for each type of
peripheral. The following table shows the available peripheral addresses and the
maximum number of addresses accepted.
The top left section of the Table shows the maximum number of assignable addresses
(5 for the SmartLiving505 model, 10 for the515 model, 20 for the 1050 model and 40
for the 10100 model) and the DIP-switch configuration of the Flex5 expansion board
(refer to paragraph 3-3-4 Addressing FLEX5 expansion boards).
The second section shows the nBy/S and nBy/X reader addresses with the
corresponding combination of the reader LEDs (refer to paragraph 3-3-5 Addressing
nBy readers).
The section on the far right shows the addresses available for the keypads (refer to
paragraph 3-3-2 Addressing the keypads).
For the Air2-BS200 transceivers, Ivy-B sounderflashers and IB100 isolator addressing
procedure, refer to the respective Installation Guides.
It is possible to connect only one Nexus device to the SmartLiving control panels,
therefore, there no addressing procedure is required.