• Dimmer - the output is a dimmer output thus the power supplied through the
terminals can be adjusted by the end-user
• Relay Use - the output is a relay output
• Home automation - if the control panel enters programming mode, the activated
output will not return to stand-by status.
• Interlocked This option enables the interlock function on the pair of terminals
which the terminal of the selected Flex5/DAC belongs to (pairs OUT1-OUT2 and
OUT3-OUT4).
In order for this to be valid, this option must be enabled for both terminals in the
pair.
Note
If the stand-by status of the output is determined by the occurrence of an event, the output will
still not return to stand-by status during programming mode.
Note
A declaration as to the type of output which is incoherent with the output itself may cause
malfunction.
Monostable time
This parameter applies to “Monostable” outputs only. This interval can be expressed in
seconds or minutes (see “info” box).
When a “Monostable” output receives an activation signal, it will remain active (On) for
the programmed time, regardless of the status of the trigger-event. In some cases,
“Monostable” outputs can be forced to standby before the programmed monostable
time runs out.
Use keys and and the number keys to set the times.
Via PC
Programming zones via the SmartLeague application is accomplished by the selection
and programming of the terminal configured as output, described in paragraph 7-6
Terminals.
7-9
Walk test
This section provides a quick and easy way of testing all the configured inputs.
After initializing the Walk test, all you need to do is walk through the protected
partitions and then check the detection capacity of the inputs via the system
keypad or SmartLeague software application.
Via Keypad
Type-in the code
(Installer)
, PROGRAMMING Walk test .
On access this section, the full list of configured zones appears on the screen.
As these input zones are violated by the operator carrying out the walk test,
they will be cleared from the list and the keypad will emit a long beep.
You can consider the outcome of test positive when there are no zones left on
the list.
Via PC
Select “Check control panel - Monitoring - Walk test” option from the menu bar.
The display will show a list of all the configured zones and the start test button.
Once you press the test button, the violated zones will be marked by a red dot.