The control panel and peripherals 25
After activation of the Fault LED (indicating a fault is present), you can obtain further
information regarding the cause of the fault by simply pressing button P2 [D]. The
successive activation of the Emergency and Fault signalling LEDs will signal as follows:
You can obtain an indication of the GSM reception level by simply pressing button P1
[C] and observing the number of LEDs which light amongst the Communication,
Emergency and the Fault LEDs (viewing lasts 5 seconds):
•1 LED - weak reception
2 LED - good reception
3 LED - excellent reception
2-4
SmartLAN ethernet interface
SmartLAN boards (SmartLAN/G and SmartLAN/SI versions) allow the expansion of
connectivity of all INIM control panels to the LAN and the Internet.
The operating capacity of the SmartLAN board depends on the proper configuration of
the networks it is connected to. Therefore, if you are installing a SmartLAN board, it is
necessary to contact the network administrator in order to configure it correctly.
Both boards allow you to programme the control panel parameters via the LAN through
the SmartLeague software programme.
The SmartLAN/G also allows users to:
send event-report e-mails and attachments.
interact with the control panel through any browser (Explorer, Firefox, Opera, Safari,
etc.), as long as it has an integrated web server. The web interface, after user
authentication, can show:
•• view the status of zones
•• view the status of partitions
•• view the status of timers
•• view the events log
•• access one of the keypads operating within the system which will provide the user
with an interface that is recognized by the control panel
Thus the user will be able to arm/disarm partitions, bypass/unbypass zones, activate/
deactivate the alarm and tamper memories.
For a more detailed explanation of how to use the Web interface, refer to the User
Manual of the control panel in use.
Table 2-39:
Fault signalling
LED On Fault
Communication
No Credit
Emergency
SIM card with PIN request enabled
Faults
Communication problems with the GSM mod-
ule
Table 2-40:
Device specifications
Expansion board models SmartLAN/SI SmartLAN/G
Power supply voltage
12V
Maximum current draw
70 mA 90 mA
Operating temperature
from -5 to +40 °C
Dimensions
81 x 54 x 25 mm
Maximum capacity of the μSD-
card
32 GByte
Security protocol
8-bit proprietary
encryption
128-bit AES
PCB code
IN074 IN133
Table 2-41:
SmartLAN - description of parts
A
RJ45 LAN line jack
B
DB9 serial line jack (on the back)
C
Ancillary power connector (SmartLiving515 only)
D
μSD-card connector
E
RESET button
F
HARD RESET button
A
B