72 Options and programming methods
Anti-intrusion control panels
7-10
Telephone
This programming section deals with all the telephone parameters.
The built-in ATS device (alarm transmitting system) provides the following features (in
compliance with EN50131 relating to the notification of information).
Type B notification apparatus (refer to EN50131-1:2008-02, paragraph 8.6
Notification, Table 10, page 46, Grade 2).
The ATS2 notification apparatus specified in the table, is characterized by:
•• Transmission time - classification D2 (60 seconds)
•• Transmission time - max. values M2 (120 seconds)
•• Classification time - classification T2 (25 hours)
•• Substitution security - S0 (no detection of device substitution)
•• Information security - I0 (no detection of message substitution)
Via Keypad
Type-in Code
(Installer PIN)
, PROGRAMMING Telephone .
Select number
The Phonebook provides 15 number slots which can be selected by means of keys
and . You can program the following fields for each selected number:
Number: edit field for the contact number (maximum 20 digits). Accepts also “,” (=
2 second pause), “*” and “#”.
Description: edit field for the name of the contact person. Follow the instructions in
paragraph 7-7 Zones.
Type:
•• None - the selected number can receive SMS text messages only
•• Voice - the selected number can receive voice calls and SMS text messages
If the number refers to the Alarm Receiving Centre, assigns the ARC protocol
(reporting format):
•• Ademco 10bps
•• Ademco 14bps
•• Franklin 20bps
•• Radionics 40bps
•• Scantronic 10bps
•• CONTACT-ID
•• SIA - Level 1 SIA is applied This reporting format (protocol) is capable of sending
descriptions of the objects in ASCII characters. if you do not wish to send the
descriptions in ASCII characters, select “No SIA strings” (refer to paragraph 7-5
Panel options). You can set a 4, 5 or 6 digit customer code for this protocol.
•• Ademco Express
•• CESA
•• SIA-IP
Use keys and to select the number type then press .
If a telephone number is “SIA-IP” type, the IP address and port of the SIA-IP receiver
must be entered in the receiver number field in the “Number” section, using the
following format:
xxxyyyzzzttt,ppppp
where:
- “xxxyyyzzzttt” are the 4 octets of the IP address (standard IPv4), each of which should
be written with 3 figures and, if necessary, “0” filler characters and no separation points.
- “ppppp” is the port and should be written with 5 figures and, if necessary, “0” filler
characters.
Account code: a 4-character alphanumeric code which identifies the caller in
reports to the Alarm Receiving Centre. Some protocols (reporting formats) accept
digits only, whilst others accept also “A, “B”, “C”, “D”, “E” and “F”, available using
keys .
Partitions: this option allows you to associate each telephone number with specific
partitions. By selecting the partitions, using Keys and , you enable/disable
the users (who have at least one of these partitions in common with the telephone
number) to modify the number concerned.
PROGRAMMING
Outputs
Walk test
Telephone
Telephone
Select number
Number of rings
Max.num.attempts
Select number
NUMBER 001
NUMBER 002
NUMBER 003
NUMBER 001
Number
Description
Type

Table of Contents