Installation 27
Chapter 3
INSTALLATION
3-1
Installing the control panel
3-1-1
Wall-mounting
The control panel should be located in a hidden place that can be accessed
by authorized building occupants only.
1. Using the backbox (Table 2-6: Control panels - description of parts, J),
mark the anchor screw locations on the wall. Be sure not to drill in the
vicinity of electrical wiring or plumbing/gas pipes, etc.
2. Insert the screw anchors (recommended size 6mm).
3. Pass the wires through fairlead glands.
4. Using the screws, attach the backbox to the wall.
5. Fit the control panel dislodgement-tamper protection (optional):
5.1. Insert the dislodgement-tamper bracket [A] into its location on
the backbox of the control panel (Table 2-6: Control panels -
description of parts, K).
5.2. Using screw location [B], screw the bracket to the wall.
5.3. Connect the wire coming from the dislodgement-tamper
microswitch [C] to the connector [D] on the board (Table 2-8:
Mother board - description of parts, J).
Note
The cable gland must be flame class rating V-1 or higher.
3-1-2
Connecting the Mains power
supply
The control panel must be powered through a separate line coming from the Mains box.
The line must be protected by a safety-standards compliant circuit breaker (trip switch).
The circuit breaker (trip switch) must be located externally to the apparatus and should
be easily accessible. The distance between contacts must be at least 3mm. The
manufacturer strongly advises the use of a magnetothermic switch with C intervention
curve and nominal (maximum) current - 16A.
The protective earthing system must be compliant with all safety standards and laws in
force.
DANGER!
Ensure that the Mains is switched Off during the mains connection phase. Danger of
electric shock.
1. Pull the power-supply wires through the wire entry [A].
2. Connect the primary power-supply to the appropriate terminals [B] (Table 2-6:
Control panels - description of parts, E).
Follow the indications on the label [C] located near the mains terminal board.
For a safety standard compliant installation the phase wire must be connected to
the “L” terminal and the neutral wire to the “N” terminal.
3. Ensure that very low safety voltage or signal wires do not come into contact with
dangerous voltage points.
Using a cable tie, bunch the wires together and connect them firmly to one of the
cable hooks on the backplate of the enclosure.
Note
The end of a stranded wire must not be consolidated with soft soldering in points where the wire
is subjected to contact pressure.