28 Installation
Anti-intrusion control panels
SMARTLIVING 505 AND
515
4. Connect the earth wire to terminal “ ” of SmartLiving505 and 515 control panels.
5. Ensure that the frontplate [D] is earthed.
SMARTLIVING 1050 AND
10100
4. Crimp the earth wire to the ring terminal [E] (included).
5. Attach the ring terminal wire to the earth screw [F] of the control panel.
6. Ensure that terminal “ ” of the power supply module [G] and the frontplate [H]
are connected to earth.
3-1-3
Connecting the backup
battery
The backup battery [A] connection must be completed during the phase described in
Chapter 4 - First power up.
The metal enclosure of SmartLiving 505, 515 and 1050/G3 control panels is capable of
housing one lead battery @12V 7Ah or 9Ah.
The metal enclosure of the SmartLiving 1050L, 1050L/G3, 10100L and 10100L/G3
control panels is capable of housing one lead battery @12V 17Ah.
Note
The battery casing must have HB flame rating or higher.
Using the battery wire [B] (included), connect the battery directly to the control panel
motherboard.
ATTENTION!
Ensure that battery polarity is correct:
- black wire = negative
- red wire = positive
Connect the cable to the control panel using the appropriate connector [C]:
For SmartLiving 505, 515, 1050 and 1050L control panel models, the connector is on
the motherboard (Table 2-8: Mother board - description of parts, B).
For SmartLiving 1050/G3, 1050L/G3, 10100L and 10100L/G3 control panel models,
the connector is on the power supply unit (Table 2-7: Power supplies - description of
parts, D).
The lead battery is the secondary power source which powers the system when the
primary (mains) power source fails (230V 50Hz).
Once powered up, the panel will charge and monitor the batteries automatically. The
panel tests the efficiency of the batteries by simulating load current demand at regular
4 minute intervals. If the control panel detects a voltage inferior to 10.4V (battery
inefficient), it will generate an Empty battery event that will not clear until the voltage
goes back to over 11.4V.
This fault will be signalled on the yellow LED on the keypads. To view the fault event,
work through the following steps:
User menu
, View , Faults .
A
B
D
N
L
MA
IN FUSE T500mA L250V
AC Input
B
A
E
F
G
H
B
A
E
F
G
H
B
A
E
F
G
H
SmartLiving 1050, 1050/G3
SmartLiving 505, 515
N
L
230V ~ 50/60 Hz
AC I
nput
C
SmartLiving 10100L, 10100L/G3
N
L
230V ~ 50/60 Hz
AC I
nput
C
SmartLiving 1050L, 1050L/G3,
N
L
230V ~ 50/60 Hz
AC I
nput
C
C
Faults
Low battery